Siemens Somatom ‘SCOPE’ 16

MODEL Siemens SOMATOM EMOTION 16
Number of slices 16
COUCH Couch top material (COUCH) Carbon fiber
Couch top length and width (cm) (COUCH) 222 x 43
Horizontal movement range (cm) (SCANNER GANTRY) 153
Horizontal movement speeds (mm/sec) (Horizontal movement speeds) 1-100
Accuracy/reproducibility of table positioning (mm) (Horizontal movement) ±0.25
Scannable horizontal range without table top extension (cm) (COUCH) 153
Vertical movement range out of gantry (cm) (SCANNER GANTRY) 45-83
Vertical movement range in gantry (cm) (Vertical movement range in gantry) 64-83
Minimum couch top height outside gantry (cm) (Vertical movement) 45
Maximum weight allowed on couch (kg) (Maximum weight allowed on couch) 200
Maximum weight on couch which still achieves stated performance specifications (kg) (Weight bearing properties) 200
Generation (SCANNER GANTRY) 3rd
Slip ring (SCANNER GANTRY) Low voltage
Aperture (cm) (SCANNER GANTRY) 70
Scan fields of view (cm) (SCANNER GANTRY) 50, extended 70 option
Tilt range (degrees) (SCANNER GANTRY) ±30
Type of positioning lights (SCANNER GANTRY Laser
Accuracy of positioning lights (mm) (SCANNER GANTRY) ±1
Focus-isocentre distance (mm) (COUCH) Focus-detector distance (mm) (COUCH) 940
X-ray generator (POWER NEEDED, VAC) Type (CONFIGURATION) High frequency
Location (COMPOSITION) Rotation assembly
Power rating (kW) kV settings available (Maximum weight allowed on couch) 50, 80,110,130
mA range and step size (Weight bearing properties) 20-345(1mA steps)
Max. mA allowed for each kV (Weight bearing properties) 80 kV: 345 mA
X-RAY TUBE:
Type and make (X-RAY TUBE) Siemens Dura 422MV Siemens Straton
Focal spot size(s) (mm), quoted to (XRAY TUBE) 0.5 x 0.8
IEC 336/93 standard (X-RAY TUBE) 0.7 x 0.8
Settings at which focal spot (X-RAY Tube) Change automatically; small changes.
kW = kV x mA / 1000 (X-RAY TUBE) up to 28 kW ; large up to 45 kW
Total filtration (inherent + beam shaping filter) at central axis (mm Al equivalent) (X-RAY TUBE) 6.3 (140kV)
Anode heat capacity (MHU) (SCANNER GANTRY) 5
Maximum anode cooling rate (kHU/min) (SCANNER GANTRY) 810
Method of cooling (X-RAY TUBE) Oil to air
Guaranteed tube life (SCANNER GANTRY) 200,000 scan seconds
Detector type (DETECTOR CHARACTERISTICS) Solid state (Ultra Fast Ceramic)
Maximum number of simultaneously acquired data sets (no. of slices) (XRAY TUBE) 16
Number of detectors per row (Maximum anode cooling rate) 736 (1472 channels)
Number of elements along z-axis (Maximum anode cooling rate) 24
Effective length of each element at isocentre (mm) (SCANNER GANTRY) 16 x 0.6, 8 x 1.2
Total effective length of detector array at isocentre (mm) (SCANNER GANTRY) 19.2
Option for more slices / rotation (Maximum anode cooling rate) Yes
MAIN CONSOLE Diagonal dimension of image screen (inches) (Image monitor) 19
Number of monitors at console (functions of each if > 1) (Image monitor) Up to 6 (shared database)
Image area matrix dimensions (Image display) 1024 x 1024
Usual range of CT number displayed (HU) (Image monitor) (-10,240 to 30,710 if metal implants)
Accuracy of distance measurements in x-y plane (mm) (Image display) Depends on pixel size
Weighted CTDI (CTDI w or CTDI vol) displayed on console (X-RAY TUBE) Yes
Dose Length Product (DLP) displayed on console (Dose information) Yes
Geometric Efficiency displayed on console when <70% (Dose information) >70% for all collimations
Control methods (SCANNER GANTRY) Mouse, keyboard
Number of slices 16
COUCH Couch top material (COUCH) Carbon fiber
Couch top length and width (cm) (COUCH) 222 x 43
Horizontal movement range (cm) (SCANNER GANTRY) 153
OTHER ATTRIBUTES (Interference compensation) Sure View; Care Dose; Heart View CT; syngo
Calcium Scoring; syngo Perfusion; CARE Vision CT
fluoroscopy; CARE Bolus; syngo Osteo; syngo
Dental; syngo Pulmo; syngo Image fusion
(CT/MRI/PET); syngo Lung Care; syngo 3-D Vessel
View; syngo Fly Through; syngo